snmptrap

什么是snmpwalk

snmpwalk是一个SNMP程序,它使用SNMP的GETNEXT请求查询指定OID(SNMP协议中的对象标识)入口的所有OID树信息,并显示给用户

以下是原英文解释:

snmpwalk  is  an SNMP APPlication that uses SNMP GETNEXT requests to query a network entity for a tree of  information.

An object identifier (OID) may be given on the command line.  This OID specifies  which  portion  of  the  object  identifier space will be searched using GETNEXT requests.  All variables in the subtree below the  given OID are queried and their values presented to the user.  Each variable name is given in the  format  specified in variables(5).

If  no  OID  argument is present, snmpwalk will search the subtree rooted at SNMPv2-SMI::mib-2 (including  any MIB object values from other MIB modules, that are defined as lying within  this  subtree).   If  the  network entity has an ERROR processing the request packet, an error packet will be returned and a message will be shown, helping to pinpoint why the request was malformed.

If the tree search causes attempts to search beyond the end of the MIB, the message “End of MIB” will  be displayed.

snmpwalk的作用

可使用snmpwalk查看支持SNMP协议的设备的一些信息,如cisco交换机或路由器IP地址等,也可用来协助开发SNMP功能。

snmpwalk的用法

snmpwalk -v 1或2(代表SNMP版本) -c SNMP读密码 IP地址 OID(对象标示符)

(1) -v: 指定snmp的版本, 1或者2;

(2) -c:    指定连接设备SNMP读密码;

(3) IP:    指定要walk的设备的IP地址;

(4) Oid:代表要获取设备的指标oid;

用法举例:

例如获取cisco设备192.168.17.191的接口类型

Snmpwalk –v 2 –c public 192.168.17.191 1.3.6.1.2.1.2.2.1.3

********************************************************************************************************************************************************

net-snmp还有trap的命令程序,可以用来测试snmp的trap方法(包括inform方法)。这些命令程序是: snmptrap、snmpinform和snmptrapd。其中:

  • snmptrap:可以模拟snmp agent发送一个trap到snmp管理端(一般称为网管,snmp manager或snmp client);
  • snmpinform:可以模拟snmp agent发送一个inform request到snmp管理端(Trap是发送给SNMP管理者的通知网络状况等的警告消息,而Inform是需要SNMP管理者确认接收的Trap。与Inform 相比较,Trap通知方式为不可靠传输,因为snmp管理端在收到一条Trap通知后无需回复任何确认信息,所以snmp agent无法知道Trap通知是否已经被snmp管理端正确接收);
  • snmptrapd:一个模拟snmp管理端接收trap/inform通知的程序;

由上可见,通过上述3个命令程序,我们可以研究snmp的trap行为及其报文,如果你正在开发snmp agent的trap功能但又没有snmp管理端,这3个程序则可帮上你的大忙。下面详细介绍这3个命令程序的具体用法。

snmptrapd的配置及其使用

snmptrapd.conf文件

跟snmp agent一样,snmptrapd也需要一个配置文件才能运行,否则会提示不能接收trap的信息。snmptrapd所需的配置文件名称为:snmptrapd.conf,安装net-snmp后,默认是没有这个配置文件的,因此需要新建此文件。snmptrapd.conf文件可放在net-snmp的安装路径下,也可放在其它路径中,但需要在启动运行时指定该文件。建立后,添加如下文件内容

1 authCommunity log,execute,net public

上面语句指明以“public”为“community”请求的snmp “notification”允许的操作[见参考资料2]。上面添加的是比较简单的配置,但可使snmptrapd程序运行起来并正确接收trap包。snmptrapd.conf文件更详细的配置及其解释参考资料[1]。

运行snmptrapd程序

1 sudo snmptrapd -C -c Documents/snmptrapd.conf -df -Lo

上面命令中的选项表示:

  • -C : 表示不使用net-snmp默认路径下的配置文件snmptrapd.conf;
  • -c : 指定snmptrapd.conf文件;
  • -d : 显示收到和发送的数据报,通过这个选项可以看到数据报文;
  • -f  : 默认情况下,snmptrapd是在后台中运行的,加上这个选项,表示在前台运行;
  • -L : 指定日志记录在哪里,后面的o表示直接输出到屏幕上,如果是跟着f表示日志记录到指定的文件中;

可通过snmptrapd -h查看命令帮助了解该命令的使用。

snmptrap的使用方法

snmptrap可模拟发送不同snmp协议版本的trap包。各协议版本的snmptrap使用方法略有不同。

发送V1版本trap报文的方法

1 sudo snmptrap -v1 -c public 10.10.12.219 1.3.6.1.4.1.1 10.10.12.219 2 3 1000 1.3.6.1.9.9.44.1.2.1 i 12 1.3.4.1.2.3.1 s test_snmptrap

上面指令各项参数的意思分别为:

snmptrap -v1 -c public 10.10.12.219 1.3.6.1.4.1.1 10.10.12.219 2 3 1000
命令 Snmp协议版本 共同体 Snmp管理端IP  Enterprise-OID Snmp代理IP Trap类型  Trap特征码 uptime
1.3.6.1.9.9.44.1.2.1 I 12 12 1.3.4.1.2.3.1 s test_snmptrap
被发送参数的OID 数据类型 数据值 被发送参数的OID 数据类型 数据值

上面中,snmptrapd和snmptrap都在虚拟ubuntu中执行的,所以snmp管理端IP和snmp代理IP一样。执行后,在执行snmptrapd的窗口中可接收到数据,如下:

04 01 01 40  04 0A 0A 0C  DB 02 01 02    .+…..@……..

0032: 02 01 03 43  02 03 E8 30  29 30 0E 06  09 2B 06 01    …C…0)0…+..

0048: 09 09 2C 01  02 01 02 01  0C 30 17 06  06 2B 04 01    ..,……0…+..

0064: 02 03 01 04  0D 74 65 73  74 5F 73 6E  6D 70 74 72    …..test_snmptr

0080: 61 70                                                 ap

2013-03-23 17:44:32 ubuntu.local [10.10.12.219] (via UDP: [10.10.12.219]:52930) TRAP, SNMP v1, community public

SNMPv2-SMI::enterprises.1 Link Down Trap (3) Uptime: 0:00:10.00

SNMPv2-SMI::internet.9.9.44.1.2.1 = integer: 12 SNMPv2-SMI::org.4.1.2.3.1 = STRING: “test_snmptrap”

snmptrapd接收到一个trap类型为2即Link Down类型,特征码为3的trap包。

发送V2版本trap报文的方法

从上面可看到,发送V1版本的trap包有较多的参数,如uptime等,而在V 2c版本中则交给了指令程序去做。

1 sudo snmptrap -v 2c -c public 10.10.12.219 "aaa" 1.3.6.1.4.1.2345 SNMPv2-MIB::sysLocation.0 s "just here"

上面指令各项参数的意思分别为:

  • 10.10.12.219 “aaa”:分别是snmp代理的IP和主机名称,主机名称可以为空;
  • 1.3.6.1.4.1.2345:企业OID,Enterprise-OID;
  • SNMPv2-MIB::sysLocation.0 s “just here”:分别是:数据OID、数据类型、数据值。

使用V2c版本,是不是省了很多,不用输入很多的参数选项。执行指令后,snmptrapd收到如下数据信息:

Received 75 bytes from UDP: [10.10.12.219]:40033

0000: 30 49 02 01  01 04 06 70  75 62 6C 69  63 A7 3C 02    0I…..public.<.

0016: 04 76 90 66  76 02 01 00  02 01 00 30  2E 30 15 06    .v.fv……0.0..

0032: 0A 2B 06 01  06 03 01 01  04 01 00 06  07 2B 06 01    .+………..+..

0048: 04 01 92 29  30 15 06 08  2B 06 01 02  01 01 06 00    …)0…+…….

0064: 04 09 6A 75  73 74 20 68  65 72 65                    ..just here

2013-03-24 10:35:50 ubuntu.local [UDP: [10.10.12.219]:40033]:

SNMPv2-MIB::snmpTrapOID.0 = OID: SNMPv2-SMI::enterprises.2345 SNMPv2-MIB::sysLocation.0 = STRING: just here

snmpinform的使用方法

snmpinform的使用跟snmptrap的使用方法是一样的,在这里就不多介绍和说明了。最后,贴上它们的使用帮助信息:

USAGE: snmptrap [OPTIONS] AGENT TRAP-parameterS

Version:  5.3.0.1

Web:      http://www.net-snmp.org/

Email:    [email protected]

OPTIONS:

-h, –help  display this help message

-H   display configuration file directives understood

-v 1|2c|3  specifies SNMP version to use

-V, –version  display package version number

SNMP Version 1 or 2c specific

-c COMMUNITY  set the community string

SNMP Version 3 specific

-a PROTOCOL  set authentication protocol (MD5|SHA)

-A PASSPHRASE  set authentication protocol pass phrase

-e ENGINE-ID  set security engine ID (e.g. 800000020109840301)

-E ENGINE-ID  set context engine ID (e.g. 800000020109840301)

-l LEVEL  set security level (noauthNoPriv|authNoPriv|authPriv)

-n CONTEXT  set context name (e.g. bridge1)

-u USER-NAME  set security name (e.g. bert)

-x PROTOCOL  set privacy protocol (DES|AES)

-X PASSPHRASE  set privacy protocol pass phrase

-Z BOOTS,TIME  set destination engine boots/time

General communication options

-r RETRIES  set the number of retries

-t TIMEOUT  set the request timeout (in seconds)

Debugging

-d   dump input/output packets in hexadecimal

-D TOKEN[,…] turn on debugging output for the specified TOKENs

(ALL gives extremely verbose debugging output)

General options

-m MIB[:…]  load given list of MIBs (ALL loads everything)

-M DIR[:…]  look in given list of directories for MIBs

-P MIBOPTS  Toggle various defaults controlling MIB parsing:

u:  allow the use of underlines in MIB symbols

c:  disallow the use of “–” to terminate comments

d:  save the DESCRIPTIONs of the MIB objects

e:  disable errors when MIB symbols conflict

w:  enable warnings when MIB symbols conflict

W:  enable detailed warnings when MIB symbols conflict

R:  replace MIB symbols from latest module

-O OUTOPTS  Toggle various defaults controlling output display:

0:  print leading 0 for single-digit hex characters

a:  print all strings in ascii format

b:  do not break OID indexes down

e:  print enums numerically

E:  escape quotes in string indices

f:  print full OIDs on output

n:  print OIDs numerically

q:  quick print for easier parsing

Q:  quick print with equal-signs

s:  print only last symbolic element of OID

S:  print MIB module-id plus last element

t:  print timeticks unparsed as numeric integers

T:  print human-readable text along with hex strings

u:  print OIDs using UCD-style prefix suppression

U:  don’t print units

v:  print values only (not OID = value)

x:  print all strings in hex format

X:  extended index format

-I INOPTS  Toggle various defaults controlling input parsing:

b:  do best/regex matching to find a MIB node

h:  don’t apply DISPLAY-HINTs

r:  do not check values for range/type legality

R:  do random access to OID labels

u:  top-level OIDs must have ‘.’ prefix (UCD-style)

s SUFFIX:  append all textual OIDs with SUFFIX before parsing

S PREFIX:  Prepend all textual OIDs with PREFIX before parsing

-L LOGOPTS  Toggle various defaults controlling logging:

e:           log to standard error

o:           log to standard output

n:           don’t log at all

f file:      log to the specified file

s facility:  log to syslog (via the specified facility)

(variants)

[EON] pri:   log to standard error, output or /dev/null for level ‘pri’ and above

[EON] p1-p2: log to standard error, output or /dev/null for levels ‘p1’ to ‘p2’

[FS] pri token:    log to file/syslog for level ‘pri’ and above

[FS] p1-p2 token:  log to file/syslog for levels ‘p1’ to ‘p2’

-C APPOPTS  Set various application specific behaviour:

i:  send an INFORM instead of a TRAP

-v 1 TRAP-PARAMETERS:

enterprise-oid agent trap-type specific-type uptime [OID TYPE VALUE]…

or

-v 2 TRAP-PARAMETERS:

uptime trapoid [OID TYPE VALUE] …

如果还不明白的,可以看一下下面的参考资料,或许对你有帮助。

参考资料

  • [1] http://blog.csdn.net/dumeifang/article/details/4201860
  • [2] http://hi.baidu.com/snailzone/item/73b4541c104154701009b590
  • [3] http://blog.chinaunix.net/uid-677314-id-83386.html
  • [4] http://blog.csdn.net/fxzhang/article/details/5408827

相关阅读

分享到:

栏目导航

推荐阅读

热门阅读